Pulse width modulated Driver Modules regulate the power supplied to the Proportionating Electromagnetic Valves based on a reference signal. Set-point signals, 0-5 Vdc or 4-20 mA, input are employed to control the output pulse width modulated voltage at a fixed frequency (ā30KHz) and amplitude. Incoming power to the valve coil is applied and discontinued for predetermined periods of time by a low loss solid state switching element.
The wide range of power input features conveniently accommodates 12 to 32 Vdc sources.
The Auto-Select feature of the Driver Module recognizes the type of reference signal received and defaults to 0 - 5 Vdc if both signals are provided.
Power Supply for Driver Module Sold Separately
|
Features:
- Set-point signals control output pulse width modulated voltage and amplitude
- Conveniently accommodates 12 to 32 Vdc sources
- Internal resettable fuse protects electronics
- Rectifier circuits prevents polarity reversal damage
- Jumper selectable ouput power allows choice of dc voltage range
Technical Specs:
|
| Specifications: | | 6ASD Proportionating Solenoid Valve Driver Module | | Connection: | | 9-pin male "D" subconnector for input/output signals. | | Power Input Required: | | +12 to 30 Vdc 1A @ 12 Vdc, 0.5A (not supplied) @ 24 Vdc via 9-pin āDā-connector or dc power jack (center positive). | | Input Signal: | | Auto-Select feature allows circuit to recognize which analog input reference (0 to 5 Vdc or 4-20 mA) signal is provided. | | TTL On/Off: | | Jumper selectable LOW (0 Vdc) OFF-HIGH (5 Vdc) on, or reverse, to select valve ON/OFF status. | | Valve Output Power: | | Jumper selectable to +15, +22, and +29 Vdc with adjacent potentiometer to obtain ±2 Vdc. | | Fuse Rating: | | An internal resettable 1.6A fuse protects the electronics on the power input. | | Polarity Protection: | | Internal rectifier circuit protects from reversed polarity on the power input. | | Operating Temperature: | | 32°F (0°C) to 122°F (50°C). | | Dimensions: | | 3"(7.62mm) Wide x 3"(7.62mm) Deep x 1"(25.4mm) High. | | CE Compliance: | | EMC Directive 89/336/EEC EN55011:1991 Group 1, Class A EN50082-2:1995. |
User Manual & Documentation:
|