Set yourself up for testing success with our pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit (4HA6522). Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.
Precise and consistent. Achieve quick, accurate, and repeatable results. Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability. Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free
Fits seamlessly into any laboratory or industry environment. Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.
|
Features:
 |
- Precise and consistent. Achieve quick, accurate, and repeatable results
- Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability
- Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free
- Has 7-inch touch screen color display (800 x 480p resolution)
- Up to 3 hardware modules can be installed on this benchtop. The installed hardware module is assigned to the measurement channel
- Up to 3 measurements can be displayed on the benchtop screen at one time and format options can be changed in settings
- Customize measurement and calibration options, create custom buffers, and more
- Equipped with a measurement stability indicator. This criteria can be adjusted in settings
- There a re reading or module specific application modes (direct and direct/autohold)
- Application-specific probes for direct measurements
- Temperature compensation can be automatic when using a temperature probe or integral temperature sensor within probe
- Galvanic isolation for measurement modules
- Non-volatile memory saves data and settings
- Permission and password settings for each user, administrator or standard level, to prevent unwanted edits or changes to benchtop options and results
- Includes help menu for support with a brief overview of the main functionalities with descriptions and video tutorial
What's Included :EC/TDS Module (4HA6000-3) (1 pc)Refillable Combination pH Electrode with BNC Connector (HA1131B) (1 pc)Temperature Probe (HA7662-TW) (1 pc)EC/TDS Probe (HA7631233) (1 pc)pH 4.01 Buffer Solution Sachets (2 pcs)pH 7.01 Buffer Solution Sachets (4 pcs)pH 10.01 Buffer Solution Sachets (2 pcs)Electrode Cleaning Solution Sachets (HA700601) (2 pcs)pH and ORP Electrode Storage Solution 25 mL (HA70300S) (1 pc)3.5M KCl Electrolyte Solution 30 mL (HA7082) (1 pc)1413 µS/cm Conductivity Standard Solution Sachets (HA70031P) (4 pcs)5000 µS/cm Conductivity Standard Solution Sachets (HA70039P) (2 pcs)12880 µS/cm Conductivity Standard Solution Sachets (HA70030P) (2 pcs)Electrode Rinse Solution Sachets (2pcs)Capillary Pipette (1 pc)Electrode Holder (HA764060) (1pc)USB-C to USB-A Cable (1 pc)
Technical Specs:
 |
-
- Specifications
-
| -
-
| -
- 4HA6522 Advanced pH / ORP Benchtop Meter
-
| -
- pH Ranges:
-
| -
-
| -
- pH -2.0 to 20.0 pH -2.00 to 20.00 pH -2.000 to 20.000 pH (±1 last significant digit)
-
| -
- pH Resolution:
-
-
| -
-
| -
- 0.1 pH, 0.01 pH, 0.001 pH
-
-
| -
- pH Accuracy
-
-
| -
-
| -
- ±0.1 pH, ±0.01pH ±0.002 pH (±1 last significant digit)
-
-
| -
- Calibration Points:
-
-
| -
-
| -
- Up to five-point calibration
-
-
| -
- Calibration Type:
-
-
| -
-
| -
- Automatic, Semiautomatic, Manual
-
| -
- Standard Buffers:
-
-
| -
-
| -
- Hanna and NIST buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
-
| -
- Custom Buffers:
-
-
| -
-
| -
- Up to 5
-
-
| -
- Custom Group:
-
-
| -
-
| -
- Option to select from eight standard buffers and user-defined custom buffers
-
-
| -
- First Calibration Point:
-
-
| -
-
| -
- Offset or Point (User Setting)
-
-
| -
-
- Isopotential Point:
-
-
| -
-
| -
- -2.000 to 20.000 pH
-
| -
- mV Range:
-
-
| -
-
| -
-2.000.0 to 2000.0 mV
-
| -
- Mv Resolution:
-
-
| -
-
| -
- 1 mV, 0.1mV
-
| -
- mV Accuracy:
-
-
| -
-
| -
- ±0.2 mV ±1 last significant digit
| -
- mV Calibration:
-
-
| -
-
| -
- Single point offset, ±2000.0 mV
| -
- ISE Range::
-
-
| -
-
| -
- 10 x 10-5 to 300.0 ppt (g/L or mg/mL)
- 5.0 x 10-3 to 10 x 105 ppm (mg/L or µg/mL)
- 1.0 to 5.0 x 107ppb (µg/L)
- 10 x 10-7 to 10.0 M (mol/L) cont=
- 10X10-4 to 10 X 104 mmol
-
| -
- ISE Resolution:
-
-
| -
-
| -
- 1, 2, 3 significant digits
-
| -
- ISE Accuracy:
-
-
| -
-
| -
- ±0.5% (monovalent ions), ±1% (divalent ions)
-
| -
- ISE Calibration Standards:
-
-
| -
-
| -
Up to five points-
| -
- ISE Calibration Type:
-
-
| -
-
| -
- All Standards, Standard Group
-
| -
- ISE Standards:
-
-
| -
-
| -
- 7 standard solutions available for each concentration unit
-
| -
ISE Custom Standards:-
-
| -
-
| -
- Up to 5
-
| -
- ISE Custom Group:
-
-
| -
-
| -
- Up to 5
-
| -
- Conductivity Range:
-
-
| -
-
| -
- 0.000 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 999.9 µS/cm, 1000 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 1000.0 µS/cm
-
| -
- Conductivity Resolution:
-
-
| -
-
| -
- 0.001 µS/cm, 0.01 µS/cm, 0.1 µS/cm, 0.001 µS/cm, 0.01 µS/cm, 0.001 µS/cm, 0.1 µS/cm
-
| -
- Conductivity Accuracy:
-
-
| -
-
| -
- ±1% of reading or ±0.010 µS/cm, whichever is greater
-
| -
- Conductivity Cell Constant:
-
-
| -
-
| -
- 0.0500 to 200.0000 /cm
-
| -
- Conductivity Calibration Type:
-
-
| -
-
| -
- Automatic, Manual
-
| -
- Conductivity Calibration Points:
-
-
| -
-
| -
- Single, Up to 5
-
| -
- Conductivity Calibration Solutions:
-
-
| -
-
| -
- 84 µS/cm, 1413 µS/cm, 5000 µS/cm, 12880 µS/cm, 80000 µS/cm, 111800 µS/cm
-
| -
- Resistivity Range:
-
-
| -
-
| -
- 1.0 to 99.9 Ω·cm, 100 to 999 Ω·cm, 1.00 to 9.99 KΩ·cm, 10.0 to 99.9 KΩ·cm, 100 to 999 KΩ·cm, 100 to 9.99 MΩ·cm, 10.0 to 99.9 KΩ·cm, 100 to 999 KΩ·cm, 1.0 to 9.99 MΩ·cm, 10.0 to 100.0 M·
- Ωcm
| -
- Resistivity Resolution:
-
-
| -
-
| -
- 0.1 Ω ·cm, 1 Ω·cm, 0.01 KΩ ·cm, 0.1 KΩ ·cm, 1 KΩ ·cm, 0.01 MΩ ·cm, 0.1 MΩ·cm
| -
- Resistivity Accuracy:
-
-
| -
-
| -
- ±1% of reading or ±0.01 ppm, whichever is greater
| -
- Total Dissolved Solids (TDS) Resolution:
-
-
| -
-
| -
- 0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
| -
- Total Dissolved Solids (TDS) Accuracy:
-
-
| -
-
| -
- ± 1% of reading or ± 0.01 ppm, whichever is greater
| -
- Salinity Range:
-
-
| -
-
| -
- 0.00 to 42.00 PSU (Practical Salinity Scale), 0.00 to 80.00 ppt (Natural Sea Water), 0.0 to 400.0% (Percent Scale)
| -
- Salinity Accuracy:
-
-
| -
-
| -
- ±1% of reading or ±0.01 ppm, whichever is greater
| -
- Salinity Resolution:
-
-
| -
-
| -
- 0.01 PSU, 0.01 ppt, 0.1%
| -
- Salinity Accuracy:
-
-
| -
-
| -
- ±1% of reading or ±0.01 ppm, whichever is greater
| -
- Salinity Calibration:
-
-
| -
-
| -
- 1 point, using 100% salinity calibration solution (% scale only)
| -
- Temperature Range:
-
-
| -
-
| -
- -20.0 to 120.0°C -4.0 to 248°F, 253.2 to 393.2 K of reading or ±0.01 ppm, whichever is greater
| -
- Temperature Resolution:
-
-
| -
-
| -
- 0.1°C, 0.1°F, ±0.2 K
| -
- Temperature Accuracy:
-
-
| -
-
| -
- ± 0.2%°C, ±0.4°F, ±0.2 K
| -
- Temperature Calibration:
-
-
| -
-
| -
- Single point, adjustable
| -
- Temperature Compensation:
-
-
| -
-
| -
- For pH: Automatic, Manual
- For Conductivity: Linear, Natural, Standard, Disabled
| -
- Reference Temperature:
-
-
| -
-
| -
- For Conductivity: 5.0 to 30.0°C (41.0 to 86.0°F, 278.2 to 303.2 K)
| -
- Temperature Coefficient:
-
-
| -
-
| -
- For Conductivity: 0.00 to 10.00%/°C
| -
- Reading Mode:
-
-
| -
-
| -
-
- Direct
- Direct/Autohold
- ISE Only: Known Addition, Known Subtraction, Analyte Addition, Anaylyte Subtraction
- Conductivity Only: Direct / USP
| -
- Basic View:
-
-
| -
-
| -
| Measurement data, Measurement Profile (if enabled), Stability Status | -
- Simple GLP View:
-
-
| -
-
| -
- Basic View Information
- For pH: pH Last calibration date, slope, offset (pH, Rel. MV - ISE Only)
| -
- Full GLP View:
-
-
| -
-
| -
- Simple GLP Information, Calibration point details (pH, ISE, Conductivity and Salinity)
| -
- Graph View:
-
-
| -
-
| -
- Basic view information, measurement versus time graph
| -
- Table View:
-
-
| -
-
| -
- Basic View Information, Table with measurements updated every second
| -
- Reading Stability Cirteria:
-
-
| -
-
| -
- Accurate, Medium, Fast
| -
- Reading Sampling Rate:
-
-
| -
-
| -
- 1000 ms
| -
Logging Type:-
-
| -
-
| -
- Automatic, Manual, Autohold
| -
- Logging Number of Records:
-
-
| -
-
| -
- 50,000 maximum per file and stores at least 1,000,000 data points per user
| -
- Logging Automatic Interval:
-
-
| -
-
| -
- 1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
| -
Logging Sample ID:-
-
| -
-
| -
- Incremental Mode, Manual
| -
- Logging Export Option:
-
-
| -
-
| -
- .CSV file format
| -
- Connectivity USB-A
-
-
| -
-
| -
- 2 ports
- Keyboard and/or Printer Input
- USB Flash Drive
| -
- Connectivity USB-C
-
-
| -
-
| -
- 1 Port
- PC Connectivity and USB-C Type Flash Drive
| -
- Connectivity Wi-Fi & Ethernet:
-
-
| -
-
| -
- FTP, Web Server (Log transfer and download), Email
| -
- Connectivity RS232
-
-
| -
-
| -
- Connecting peripherals
| -
- Calibration Reminder:
-
-
| -
-
| -
- Daily (0 minutes to 23 hours and 59 minutes), Periodic (1 minute to 30 Days, 23 hours adn 59 minutes), or Disabled
| -
- Users:
-
-
| -
-
| -
- Up to 9 users and the default administrator account
| -
- Power Supply:
-
-
| -
-
| -
- DC adapter 100-240 VAC to 24 VDC 2A
| -
- Environment:
-
-
| -
-
| -
- 0 to 50°C / 32 to 122°F / 273 to 323 K maximum 95% RH non-condensing
| -
- Dimensions:
-
-
| -
-
| -
- 205 x 160 x 77 mm (8.0 x 6.2 x 3.0")
| -
- Weight:
-
-
| -
-
| -
- 8.05 lbs
|
User Manual & Documentation:
|

| You may also be interested in the following products: |
|
|
|

|