| Specifications: |  | 6ASD Proportionating Solenoid Valve Driver Module | 
| Connection: |  | 9-pin male "D" subconnector for input/output signals. | 
| Power Input Required: |  | +12 to 30 Vdc 1A @ 12 Vdc, 0.5A (not supplied) @ 24 Vdc via 9-pin “D”-connector or dc power jack (center positive). | 
| Input Signal: |  | Auto-Select feature allows circuit to recognize which analog input reference (0 to 5 Vdc or 4-20 mA) signal is provided. | 
| TTL On/Off: |  | Jumper selectable LOW (0 Vdc) OFF-HIGH (5 Vdc) on, or reverse, to select valve ON/OFF status. | 
| Valve Output Power: |  | Jumper selectable to +15, +22, and +29 Vdc with adjacent potentiometer to obtain ±2 Vdc. | 
| Fuse Rating: |  | An internal resettable 1.6A fuse protects the electronics on the power input. | 
| Polarity Protection: |  | Internal rectifier circuit protects from reversed polarity on the power input. | 
| Operating Temperature: |  | 32°F (0°C) to 122°F (50°C). | 
| Dimensions: |  | 3"(7.62mm) Wide x 3"(7.62mm) Deep x 1"(25.4mm) High. | 
| CE Compliance: |  | EMC Directive 89/336/EEC EN55011:1991 Group 1, Class A EN50082-2:1995. |